IFC 4.4.0.0 build 20261005 (IFC4X4_DEV_20260525) ⚠ buildingSMART Working Draft. All content is under development.

  • Help suggest improvements
  • Get user or developer support

6.3.4.6 Pset_DiscreteAccessoryLadderTrussConnector

6.3.4.6.1 Semantic definition

Shape properties specific to connecting accessories in truss form with straight cross-bars in ladder shape.

6.3.4.6.2 Applicable entities

6.3.4.6.3 Properties

Name Property Type Data Type Description
LadderTrussHeight IfcPropertySingleValue IfcPositiveLengthMeasure

The overall height of the truss connector.

LadderTrussLength IfcPropertySingleValue IfcPositiveLengthMeasure

The overall length of the truss connector.

LadderTrussCrossBarSpacing IfcPropertySingleValue IfcPositiveLengthMeasure

The spacing between the straight cross-bars.

LadderTrussBaseBarDiameter IfcPropertySingleValue IfcPositiveLengthMeasure

The nominal diameter of the base bar.

LadderTrussSecondaryBarDiameter IfcPropertySingleValue IfcPositiveLengthMeasure

The nominal diameter of the secondary bar.

LadderTrussCrossBarDiameter IfcPropertySingleValue IfcPositiveLengthMeasure

The nominal diameter of the straight cross-bars.

Table A

Edit on Github

2 contributor(s): ArturTomczakbSI-Bot
Last change: Improve definition split (#876) * bring back headers headers were previously removed by mistake, now bringing them back * add new lines and rename the tag add the word 'short' in it * unify newlines make exactly one newline before and two after the tag * resolving typos Because bringing back headers required to go back in time to previous version, I'm now re-resolving the issues: #861, #860, #856 by ArturTomczak on 2024-07-16T16:07:28+02:00

Is this page difficult to understand? Let us know!

6.3.4.6.4 Changelog

6.3.4.6.4.1 IFC4

6.3.4.6.4.2 IFC4.3_ADD2