IFC 4.4.0.0 build 20261005 (IFC4X4_DEV_20260525) โš  buildingSMART Working Draft. All content is under development.

  • Help suggest improvements
  • Get user or developer support

6.6.4.10 Pset_Stationing

6.6.4.10.1 Semantic definition

Specifies stationing parameters for IfcReferent.

6.6.4.10.2 Applicable entities

6.6.4.10.3 Properties

Name Property Type Data Type Description
IncomingStation IfcPropertySingleValue IfcLengthMeasure

The optional station value of the incoming segment that ends at this location. This value needs to be set if the intention is to specify a station equation, i.e. a location where stationing changes.

Station IfcPropertySingleValue IfcLengthMeasure

The station value at this location.

HasIncreasingStation IfcPropertySingleValue IfcBoolean

Inform on the increasing or decreasing progress of stationing values, for referents nested in a given alignment.

If present and true, or if not present, then the relevant subsequently nested referents are expected to have greater Pset_Stationing.Station values (i.e., increasing stations).

If present and false, then the relevant subsequently nested referents are expected to have lower Pset_Stationing.Station values (i.e., decreasing stations).

Table A

Edit on Github

2 contributor(s): ArturTomczakbSI-Bot
Last change: Improve definition split (#876) * bring back headers headers were previously removed by mistake, now bringing them back * add new lines and rename the tag add the word 'short' in it * unify newlines make exactly one newline before and two after the tag * resolving typos Because bringing back headers required to go back in time to previous version, I'm now re-resolving the issues: #861, #860, #856 by ArturTomczak on 2024-07-16T16:07:28+02:00

Is this page difficult to understand? Let us know!

6.6.4.10.4 Changelog

6.6.4.10.4.1 IFC4.3_ADD2

  • New resource